VFD Hz to RPM Calculator

VFD frequency to motor or conveyor speed: rpm or m/min per Hz from the nameplate, gearbox and roller, or from two measured speeds, with the slip factor.

Scaling

Measured points

Frequency
Speed
Point 1
Point 2
three or more give the best-fit line

From motor and roller

Motor
Transmission
i
Drive

Check a point
Frequency
Speed
Check
—
Measured
same frequency

—

Target
—
Use the measured point as
Results

VFD speed from frequency: Hz to rpm and m/min

A VFD sets a frequency; the line gives the speed that comes out. For the motor shaft that is the rated speed divided by the rated frequency (a 1450 rpm, 50 Hz motor runs about 29 rpm per Hz); for a conveyor, divide by the gearbox ratio and multiply by the roller circumference. The page draws this theoretical line from the nameplate, the gearbox and the roller, and fits the measured one from two points you took with a tachometer, or a stopwatch and a mark on the belt.

The factor between them is what the frequency scaling in a drive or a PLC needs correcting by: 0.97 means slip, belt creep or a roller that is not the diameter on the drawing cost 3 %. The offset should be zero; a measured line that does not pass through zero points at a minimum-frequency setting or a bad reading. Enter the drive's maximum frequency and the speed at that point is shown, including above the rated frequency, where the torque falls off.

Use the rotary output for rpm at the gearbox shaft and the linear one for m/min or ft/min on a belt. A target speed in the check point returns the frequency that reaches it, which is the setpoint to write to the drive.

How it works

Every scaling here is one straight line: value = gain × raw + offset. Two measured points fix it: gain = (value₂ − value₁) / (raw₂ − raw₁) and offset = value₁ − gain × raw₁. The gain is the scaling factor a PLC or NC axis asks for, and 1 / gain is the same thing the other way round: counts per millimetre, hertz per metre a minute.

Measured more than twice? Add up to eight points and the line becomes the least-squares fit: the one with the smallest sum of squared distances to every point. Each point then shows its residual, how far it was measured off the line; one that stands out from the rest is usually a misread or a point taken while the axis was still moving.

Worked example. An encoder reads 0 at the home position and 100 000 counts 2500 mm further on. gain = 2500 / 100000 = 0.025 mm per count, 40 counts per millimetre, offset 0. The encoder itself says the same: 1000 pulses per turn, read ×4, on a 100 mm feed, is 100 / 4000 = 0.025 mm.

Measured points define the line whenever they are filled in. The mechanics give the theoretical line: on its own it is the line, next to measured points it is the dashed comparison, and the measured one is divided by it. A factor of 0.97 means the belt runs 3 % slower than the motor and roller say it should. Each scaling has its own theory.

Encoder counts

feed ÷ (PPR × evaluation × ratio)

Position per count from the pulses per turn, the ×1/×2/×4 evaluation, the feed per turn and the gear ratio. Also the pulse rate at top speed, to check the input terminal.

Show this example

Drive frequency

n ÷ f ÷ i × π × D

Speed per hertz from the motor's rated speed at its rated frequency, the gearbox ratio and the roller diameter. Measured below it: slip.

Show this example

Speed setpoint

π × D ÷ i

Speed per setpoint turn from the gearbox and the roller: the effective feed constant of the axis.

Show this example

Analog input

raw range → value range

A 4–20 mA or 0–10 V signal arrives as a raw integer, 0–27648 or 0–32767. Map its ends to the sensor's range and read any value in between.

Show this example

Check a point looks up any raw value on the line, or slides along it. Type what you measured there and the difference is shown, as a value and a percentage; if that point is the better one, make it point 1 or 2 and the line moves through it, or add it as a new point. A target value gives the raw value that reaches it: the frequency for a conveyor speed, the count for a position.

The offset is where the line crosses zero. For an encoder it is the reference position; for a drive it should be 0, and a line that does not pass through zero points to a minimum frequency, a dead band or a measuring error.

Questions

How do I convert VFD frequency to motor rpm?

Motor speed scales with frequency: rpm = rated speed × frequency / rated frequency. A 4-pole motor rated 1450 rpm at 50 Hz runs about 29 rpm per Hz, so 35 Hz gives 1015 rpm. Use the nameplate speed, not the synchronous one (120 × f / poles, 1500 rpm here): the difference is the slip under rated load.

How do I calculate conveyor speed from the drive frequency?

Belt speed = motor rpm / gearbox ratio × π × roller diameter. A 1450 rpm, 50 Hz motor through a 20:1 gearbox on a 100 mm roller gives 1450 / 20 × π × 0.1 = 22.8 m/min at 50 Hz, or 0.456 m/min per Hz. Measure the belt at two frequencies and the page fits the real line next to this theoretical one.

Why is the measured speed lower than the frequency predicts?

Slip changes with load: the nameplate speed holds at rated load, an overloaded motor runs slower and an unloaded one faster, up to the synchronous speed. The belt can also creep on the drive roller, and the roller's effective diameter is not the drawing value once belt thickness and wear are counted. The page divides the measured scaling by the theoretical one: a factor of 0.97 means the belt runs 3 % slower than motor, gearbox and roller say.

Should the frequency line pass through zero?

Yes: at 0 Hz the motor stands still, so the offset should be 0. A measured line with an offset points to a minimum or skip frequency set on the drive, slip that differed between the two measurements because the load changed, or a reading error. Take the two points well apart, at 20 and 50 Hz rather than 45 and 50, so a small error in either does not tilt the line.

Can the motor run above its rated frequency?

Yes, and the line continues: a 1450 rpm, 50 Hz motor at 87 Hz runs about 2520 rpm. Above the rated frequency the drive cannot raise the voltage any further, so the available torque falls roughly with 1 / f (field weakening) while the speed keeps rising. Enter the drive's maximum frequency and the page shows the speed at that point.

Can I get rpm per Hz at the gearbox output shaft?

Yes. Pick the rotary output and the speed is in rpm after the gearbox: rated speed / rated frequency / gearbox ratio. The example motor (1450 rpm at 50 Hz through 20:1) gives 1.45 rpm per Hz at the output shaft; leave the gearbox ratio at 1 for the motor shaft itself.

Need saved scalings and PDF export?